2TB SAS 2. el 31-03-2017 06:19 AM. installing ESXI on HP ProLiant ML310e Gen8 v2 -- E. On This Page. 04 1: 1 The HP Dynamic Smart Array B110i/B120i/B320i controller driver for Ubuntu 12. Hello, I do have proliant ml310e server with 8x300Gb SAS HDDs. dd to . On = ROM reads configuration as invalid 3, 4, 7, 8, 9, 10, 11, 12 — Reserved . I want to expand the Raid with 2 more Disks. 09 (B) Optional ; cp031053. • Flexible configuration options—these options allow businesses to meet varied computingHPE ProLiant DL320e Gen8 v2 Server - Option Parts. Procedure. can't find graphic driver of hp proliant ml310e gen8 v2 for windows server 2003. Intel Xeon E3-1230v2 Quad-Core 3. I was told that my setup is using a 'FakeRAID' and its best to get a HW RAID card. IOCREST IO-PEX40152 with 4 x 2TB Sabrent Rocket 4 NVME. 89 x 18. It supports various operating systems, firmware, and storage controllers. Hp proliant ml310e generation 8 (gen8) v2 (43 pages) Server HP ProLiant ML310e Specification. exe. Muchas gracias!. xx is the RVU identifier. . in this thread in this sub-forum in the entire site. HP Dynamic Smart Array B120i,. Follow. The iLO 5 Configuration Utility screen. Lelecteurestmembred'un oudeplusieursdisques Orange/vertclignotant logiquesetlesystème préditladéfaillancedu lecteur. See: Poor SQL performance on HP ProLiant ML310e Gen8 v2 with raid10. But i cannot access the Raid Controller -> HP Smart Storage Administrator anymore. 211 and 12. Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. 5 x 47. Revision History. NOTE: Off is the default position as shipped from HP. Run Array Configuration Utility . 2, controller raid is embedded B120i. 83 MB Table of Contents. Browse All Products. The bundle also contains Windows NIC drivers for the HP Broadcom 1Gb Ethernet NICs and system ROMs for the HP ProLiant. Page 46: Sspadapterswithaccess array, as long as the operating system. . enabling faster deployment and configuration • HP Insight Online with HP Insight Remote Support provides 24x7 remote monitoring and. The HP Offline Array Configuration Utility provides an ISO image that can be mounted, burned to a CD/DVD, or flashed to a USB memory key or SD card by using the HP USB Key Utility for Windows. HPE ProLiant ML310e Gen8 Server: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. HP ProLiant DL320E G8 V2 Server - In our video, we will provide a simple and efficient overview focused mainly on memory and processors. I'm not sure if the HP ProLiant ML310e G8 v2 is compatible with Solid State. 5 on Esxi 6. ML310e Gen8 v2 will not boot after enabling the Hyper-V role. $149. info@upsys. I can reach the iLO webinterface but the Server hangs on the early windows 2012 system initialization on 90 % . Hit F9 to enter the ROM-Based Setup Utility (RBSU). Fired up HP Array Configuration Utility (HP-ACU). 5in SC ENT HDD 781518-B21. Reboot into BIOS Setup (press F9 ), switch to Legacy SATA. Learn about the server's performance, memory, storage, power, and more. c. I need to setup the raid 1, can you please help. Over 32,000 customers in 100+ countries trust Global One Technology to deliver mission-critical HP Enterprise hardware - including Fortune 500 businesses,. But with a different driver I get normal performance and with an up-to-date driver I get shit performance. Confirmar tipo. SRV1 is ProLiant ML310e Gen8 v2 where D: is RAID10, 4 disks. View All (2) 3 REPLIES 3. I have the following drives –. HPE ProLiant ML310e Gen8 Server: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. HP ProLiant ML310E Gen8 V2 8x 2. Goto the Advanced tab and then choose IDE configuration hit Enter. I tried to install HP Raid driver 5. HPE ProLiant ML310e Gen8 v2 Server: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. Jan 27, 2015 at 12:30. 2. The Ubuntu 12. 6-10 HP ProLiant ML310 Server Setup and Installation Guide. El direccionador VPN inalámbrico HP PS110 802. According to the HP ProLiant ML310e Gen8 QuickSpecs , below are the HP SDDs that are compatible for the HP. For a good basic NAS all you really need is a Ras Pi 4 and a USB 3 HDD. Hello everyone, i've just purchased a ML310e Gen8 v2 with xeon processor (Haswell generation), 8 GB ram, 2x1TB Hp SATA drives running on raid 1. 30 for linux user guide (68 pages) Download Software. 2] [Số HDD có thể gắn vào 4] Card RAID Dell PERC H310 Integrated RAID Controller Card (RAID 0,1,10,5,50 and JBOD) [price: 2,300,000 VNĐ]Hello, I have a HP ProLiant ML310e Gen8 v2 build using a USB to boot FreeNAS, been using it for 5 years now and it started to degrade in performance and long boot times, so i bought a cheap 120GB SSD (patriot blast) and connected it to the sata port. Hot Network QuestionsQuickSpecs HP ProLiant ML310e Generation 8 (Gen8) Technical Specifications System Unit Tower Dimensions 14. The webpage provides the user guide for HPE ProLiant DL380 G6 Server, a high-performance and energy-efficient server for data centers. QuickSpecs HP ProLiant ML310e Generation 8 (Gen8) v2 Technical Specifications System Unit Tower Dimensions 14. 0! Therefore, I installed VMWARE ESXi 6 on the server and it works very well. HP ProLiant ML310 Server Setup and Installation Guide. RAID,unemigrationde tailledestripe,une extensiondecapacitéou uneextensiondedisque logique,ouestencours d'effacement. Should the customer need additional hard drive blanks, they can order more using either P/N 666987-B21: HP SFF Gen8 Hard Drive Blank Kit or P/N 666986-B21: HP LFF Gen8. 00] HP P822 Smart Array 6Gb/s RAID Controller w/ 2GB Cache and. Learn how to set up, configure, and operate your HPE ProLiant MicroServer Gen8 with this comprehensive user guide. Storage controllers 1 HP Smart Array B120i SATA RAID Expansion slots 4 Management HP iLO 4 Management. There are two 1 TB HDDs in Raid 1 with 400GB logical drive that i configured through HP provisional tool Windows installs just fine but cant boot into it. 1. exe . 0. Choose RAID from the drop-down list. Lo más seguro es que no haya para W81 ó Win10, elige 2008 ó 2012 Server, tanto controladores como sistema operativo deben ser de 64bit. Follow. Hp proliant ml310e generation 8 (gen8) (43 pages). This system is feedback driven thru Solution and Kudo flags. 000. (Raid 1) Low set resolution on Proliant ML30 Gen10, Win Server 2019 ML10 gen9 SSD upgrade Network wifi hp probook - dns problem Weak SSL/TLS Key Exchange on HP iLO View all topics. About ACU. fiz a troca dos HDs por novos para realizar a instalação, ja fiz o raid deles. ۹۱۰۰۳۰۹۰ -۰۲۱HPE ProLiant ML310e G8 v2 Server Superior SATA. Download Software. (Click to enlarge) To run HP-SUM, download the SPP software at hp. 5. On Bootup screen it says press F5. may have older product names and model numbers that differ from current models. 99Download Software. Installation. Should the customer need additional hard drive blanks, they can order more using either P/N 666987-B21: HP SFF Gen8 Hard Drive Blank Kit or P/N 666986-B21: HP LFF Gen8. I searched for a couple of days and noticed that the latest version of ESXi which supports HP ProLiant ML310e Gen8 v2 is VMWare 6. 4) 2TB Seagate HHD. I just purchased a "refurbished" ML310e Gen8 with a P410 array. Hp proliant ml310e generation 8 (gen8) (43 pages). We checked and Win10 is not listed as a supported version of operating system and this is the possiblity that you are not getting option for F8-safe mode. Incorporating key HP technologies from the HP ProActive Insight architecture, the ML310e Gen8 v2 provides innovations in memory, server management, and. I have a HP ProLiant ML310e G8 v2 with Intel® Xeon® E3-1220v3 3. Press <F5> to run HP Array Configuration Utility (ACU) Press <ESC> to skip * Boot Logical Drive s configured but is Missing or Offline. Thanks for the HP mention md0221. First of all it serves about 15 computers and it has these purposes: web server (apache), mailserver (postfix/dovecot) and provides local backup for the important documents on the. For your server, please answer my question about RAID configuration and the type of controller in the server. Page 1: User Guide. System Options. Hewlett Packard Enterprise believes in being unconditionally. Install OMV and you can have NAS functions, a Web Server with PHP support (NGINX), MariaDB, Transmission Bit Torrent, Plex Server and technically Docker (though it really won't run anything X86 based). 5 x 47. • HP Insight Online with HP Insight Remote Support provides 24x7 remote monitoring and. QuickSpecs HPE ProLiant ML310e Generation 8 (Gen8) v2 Standard Features Page 2 NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. 04. 11n y el conmutador HP PS1810-8G son opciones de conexión en red complementarias para el HP ProLiant MicroServer Gen8. What's New. When the system maintenance switch position 6 is set to the On position, the system is prepared to erase all system configuration settings from. CONREP is shipped in the. 5 inch atau HP 300GB x2 Sas 2. Installed Server 2012 R2 and all HP drivers from the HPE SPP 8. Producto: Proliant ML310e Gen8 v2 Sistema Operativo: Microsoft Windows Server 2012. 2 drive in it should be recognised and accessible. Standard Features. HPE ProLiant ML310e Gen8 v2 Server: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. Hp proliant Dl380p gen 8 power issue. 04: 02 June 2019: cp039751. Availability: Usually Ships in 4 to. HP ProLiant Servers Troubleshooting Guide October 2003 (Second Edition) Part Number 338615-002 HP CONFIDENTIAL File Name: 338615-2. 5" Drive. It is ideal for remote sites and corporate branch offices running file/print, web messaging, and small vertical applications or databases. SSD Over Provisioning Optimization – optimizes Solid State Devices by de-allocating all used blocks before any data is written to the drive. item 6 HP ProLiant ML310e G8 Server Motherboard- 730279-001 HP ProLiant ML310e G8 Server Motherboard- 730279-001. 1. Para ese servidor la tarjeta de red podría ser HP Ethernet 1GB 2-port 332i y le puedes poner los controladores de 2008 Server R2 64bit. I downloaded from the site of the raid controller driver. 000. Get Started. latest you can. 0 がサポートされてい. 0 using hpvsa-1. 71 in (36. This document provides detailed information on the hardware features, specifications, installation, configuration, and troubleshooting of the server. I can see this server it's not hotswap. Refurbished to an extremely high standard and with a 12 month. Si el controlador va embutido en un exe o zip debes. Me sale una alerta en el servidor a cuenta de los discos raid. With the Proliant I have four LFF (3. By default, server boot behavior is controlled by the server profile or server profile template. Should the customer need additional hard drive blanks, they can order more using either P/N 666987-B21: HP SFF Gen8 Hard Drive Blank Kit or P/N 666986-B21: HP LFF Gen8. 4. Add External Storage RAID Controller Add Fibre HBA Controller. Operating System Support for the HPE ProLiant BladeSystem portfolio is frozen starting from Service Pack for ProLiant (SPP) Version 2021. Electrical specifications. Reboot the server. Criei o array com raid 1, porém quando vou tentar fazer a instalação com ESXI 6. QuickSpecs HP ProLiant ML310e Generation 8 (Gen8) v2 Standard Features c04123183 – DA – 14564 Worldwide — Version 15 — June 10, 2014 Page 2 NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. RBSU Menu > Advanced Options > Embedded SATA Configuration > Enable SATA AHCI Support. If the disks you're using are not HP drives and you're using a Gen8 ProLiant server, there's no guarantee that the disks will be recognized or will even work reliably. Optional 😉: shut down the box and swap the cables on ports 5 and 6. Compatible with that latest Intel Xeon E3, Core i3 and Pentium G (IvyBridge) series processors and 4 DIMM slots for up to 32GB of DDR3 memory. Navigate to SATA Controller Options -> Embedded SATA Configuration 3. accommodate changing business needs. Delivers essential availability and device name. If you keep the SATA drive with Win10 on, and plug the M. 5 ele apenas localiza os discos separados. Processor One of the following depending on model Entry ProcessorsThe HP Dynamic Smart Array B110i/B120i/B320i controller driver for Ubuntu 12. 8. 5") drive bays. ”. Hello, i've the server HP Proliant ML310e g8 v2 and i'm trying to setup raid 1 with 2 new HD. Next go into the BIOS it should show two options; 1) B320i - intelligent RAID card. 3,779. Summary of Contents for HP ProLiant DL360p Gen8. HP's latest ProLiant DL320e Gen8 v2 is aimed at micro/small businesses wanting a powerful, compact and affordable server. Or you can use HP Smart Array P421 to add more drives. proliant ml310e gen8 drivers windows windows server 2003 drivers - 4537652. Operating System: Microsoft Windows 10 (64-bit) Hi I have this scenario. Type HP SmartMemory DDR3 Unbuffered (UDIMM) DIMM Slots Available 4 Maximum Capacity (UDIMM) 32 GB (4 x 8 GB UDIMM) NOTE: HP memory from previous generation servers are not fully compatible with the HP ProLiant ML310e Gen8 v2 Server. dd. 1. I want to do hot swapping work to install new disk in the server. Can't figure out why HP Gen8 drive LEDS aren't working. 0 U2I just had a disk failure on one of my physical drives of a RAID 1 logical drives, on a HP Proliant Gen8 v2 Server running Windows 2012 R2. 2TB (4 x 500GB) 7. ProLiant ML. 5U1. The bundle also contains Windows NIC drivers for the HP Broadcom 1Gb Ethernet NICs and system ROMs for the HP ProLiant ML310e/DL320e Gen8 v2 servers. #fixServer#nodisplay #bootingThe HPE sight will have the authoritative answer to your question as well as other important information you should know if you're working with an HPE server. Page 1 User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. RAID Levels. Before you do anything do a boot up into the Intelligent Provisioning software and goto the settings area, go to the HP Smart Array setup and completely clear the RAID configuration, save and exit and reboot the system. Showing 10 of 10. Sep 07, 2023. Sep 07, 2023. Step 3. You have a number of options available to you for preparing a new, modern ProLiant Gen8 server for use. No FBWC support. Windows 2012 had been running. 5 or 6). The webpage also offers links to download drivers, firmware, and software updates for the. BIOS - System ROM: Online ROM Flash Component for Windows - HP ProLiant ML310e Gen8 (J04) Servers: 2019. QuickSpecs HP ProLiant ML310e Generation 8 (Gen8) v2 Standard Features DA - 14564€€€Worldwide — Version 12 — January 31, 2014 Page€ 4HPE ProLiant ML310e Gen8 v2 Server is a versatile and affordable server that can handle various workloads and applications. iLO resets to the factory default settings. That’s why the SATA RAID controller need to be ENABLED in the BIOS Setup. x86_64. Data diperbarui pada 08/11/2023. "HP. . Home > Hardware > Servers > HP ProLiant Servers > HP Tower Servers > HP ProLiant ML310e Gen8 > HPE ProLiant ML310e G8 v2 Server Basic SAS. 1 on a HP Proliant ML310e Gen8 V2 Server. " Go to the page and run the application. 10. Whenever a "shutdown" or "reboot" server znachёk "Speakers" in the taskbar headlines. um driver de midia necessario ao computador esta. Both servers has a C: which is a RAID1. Select the latest release of the HP Lights-Out Online Configuration Utility for Linux (or HPE ESXi Utilities Offline Bundle for VMware). "HP. Please note that I got an error when I tried to configure ILO fro. Jual Beli Server Proliant Ml310e Gen8 V2. 5GHz/4-core/8MB/45W) FIO Processor Kit. Intelligent Provisioning assists with the OS installation process by preparing the system for installing "off. Processor One of the following depending on model Entry Processors HP ProLiant DL380e Gen8 - Cant Access Raid Controller. the controller defaults to a RAID configuration based on the size and number of hard drives installed. 4 on HP ProLiant DL380e Gen8 serverThe big issue I have is that if you switch off the internal RAID and make the front. Eugenijus is correct you can configure Solid State Drives (SSD) as you do spinning drives (HDD) as Eugenijus mentioned RAID options depends on the RAID controller in your server. HP ProLiant ML310e Gen8 v2 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. Put in your server type and how much total memory you want. My question is that, what other operation is needed to replace the hard disk?. Add External Storage RAID Controller Add Fibre HBA Controller. HPE ProLiant ML310e Gen8 v2, a single-socket 4U tower server, delivers essential availability and expansion needed to. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels. The bundle also contains Windows NIC drivers for the HP Broadcom 1Gb Ethernet NICs and system ROMs for the HP ProLiant. Good evening, I have a customer with a degraded Raid1+stripe, server is Ml310 G8 v. 0m 0MB) 0 Logical Volume. • HP Insight Online with HP Insight Remote Support provides 24x7 remote monitoring and. There is 1 logical drive and 2 physical drives of 1 TB each . NOTE: epending on the memory configuration and processor model, the memory speed may. Hi, the ML310e Gen8 has a Dynamic Smart Array B120i RAID controller onboard. iLO network link up at 10 Mbps. Secondly, a server is not a personal computer. My HP Account . Product: hp proliant ml319e. Join HPE President and CEO Antonio Neri and influential industry leaders to. Consistent with FAR 12. 0 | HP Proliant ML310e Gen8 v2 | Xeon E3-1230 v3 3. 71 in (36. I have an HP Proliant ML310E Gen 8 with 24GB RAM, Xeon E3. Producto: HP PROLIANT ML310E GEN8 V2. Thought is it possible if I buy two extra HP 1. spesifikasi: intel Xeon E3-1220 v3. CentOS 6. The BIOS offers "Boot from hard drive" without giving the option to select which drive or specify order. ML310e Gen8: Ubuntu 14. I booted the server once, setting up the raid 1, and messed with the configuration pannels. Avec de "petite" modification des paramètres du BIOS, j'y ai installé PROMOX et un VM de Synology. This document covers the hardware features, software installation, troubleshooting tips, and safety precautions of your server. 8 E3-1220, and the built in Raid controller is HP. Showing 7 of 7. Downloads: 118. 8 lb (18. Embedded Flash/SD-CARD: Restarted. Tags (2) Tags: Archived. order more using either P/N 666987-B21: HP SFF Gen8 Hard Drive Blank Kit or P/N 666986-B21: HP LFF Gen8 Hard Drive Blank Kit. 先日、ML310e Gen8 v2にWin10Pro(20h1)をインストして見ました。HDDはP222に2台づつRAID1を組んで、そのままBOOTドライブとしました。BIOSはBOOT順をいじったくらいですね。不明なデバイスはILO関係とB120i関係でHPよりドライバ(Server用)を落としてき. Smart Buys HP ProLiant ML310e Gen8 Processor(s) (1) Intel® Xeon® E3-1220v2 (3. 2. HPE Fibre Channel Drives - Model Number Matrix. ProLiant ML310e G8 v2 Server Basic SAS Custom Server Custom Field 5: G8 Stock Status:In Stock. Greetings everyone, I have an HP Proliant ML310e Gen8 v2 with 4 drives in a RAID 10 configuration. Both HDDs are connected in the internal 4-bay unit (Boot drive in slot 1) There are no USB devices connected with the exception of a plain USB keyboard. It is compatible with the HP 1810 Switch Series (8-port and 24-port), extending the benefits of HP Converged Infrastructure. g. I searched for a couple of days and noticed that the latest version of ESXi which supports HP ProLiant ML310e Gen8 v2 is VMWare 6. Poseo un SERVIDOR HP PROLIANT ML310E GEN8, que se adquirio el 2014, estuvo funcionando correctamente, pero de un momento a otro el windows server 8 R2 Enterprise se detuvo y lo que tuvo que hacer es reiniciar el servidor, pero al levantar el servidor ya no reconocia los discos duros. 2 drive plugged into a PCIe slot. Mixing of other drives types is not supported. A SanDisk Extreme USB 3. Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. • RAID 0,1,10 standard. 16 GB. Lelecteurn'estpas configuréetlesystème Orangeclignotant préditladéfaillancedu lecteur. iLO notifies you:Comprised of Smart Update Manager (SUM) and Service Pack for ProLiant (SPP), which reduce time-consuming, expensive, and error-prone updates. Porem quando começa a instalação ele pede para escolher o driver a ser instalado. QuickSpecs HPE ProLiant ML310e Generation 8 (Gen8) v2 Standard Features Page 2 NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. I can vSphere client. When prompted to confirm the reset, press Enter. F11 tries to boot from the NIC which is plugged in but just comes back no available boot device and F11 doesnt give me any RAID based config. Buen dia mi pregunta es como agrego un disco duro nuevo a mi servidor HP Proliant Ml310e Gen8 el mismo cuenta don windows 2008 server memoria de 16 gb y dos discos de 2 TB con Array 1, necesito agregar un nuevo disco duro para respaldar los back ups de mi base de datos, el disco nuevo es HP de 2 TB necesito que. Luego al ir arrancando verá pasar en pantalla F5 ACU-SSA y debe entrar a armar su arreglo. Customers from Global One Technology. However, I am unable to find the correct storage and/or storage controller driver that would work and allow me to install Windows 10 64-bit. ParityGroups When you create a RAID 50 or RAID 60 configuration, you must also set the number of parity groups. . 02 (B) Optional . Improve this answer. Antes de instalar Win2003 desactiva en el Bios el soporte de Raid basado en hardware. Logged in to windows (server 2008R2). 3. Waited for windows to boot. Power down the server (on page 18). The technologies behind them are engineered for different purposes. Description. Free download driver for all devices Hewlett-Packard ProLiant ML310e Gen8 v2. サーバーには次の7個のUSBコネクターがあります。. The server hardware type determines the available options in the server profile or server profile template. (98 pages) Server HP ProLiant DL320e Gen8 User Manual. Live keynote from Barcelona. I have to install windows server2008 R2 x64. HP ProLiant DL320e Gen8 v2 (P80) Servers 2015. Level 1. HP LJ M25-M27 Scan Drv; HP LaserJet Professional M1130 MFP Series; HP Officejet Pro 8600 (USB) HP Printer (BIDI). DSM 6. 99. Files. My issue is, I have no status LED's on the drives in the array. Quick removal access panel 1. Product Bulletin, research Hewlett Packard Enterprise servers, storage, networking, enterprise solutions and software. In configuration I have created an array with two disks -. There are two channels per server with two DIMM slots per channel. update . The webpage provides the user guide for HPE ProLiant DL380 G6 Server, a high-performance and energy-efficient server for data centers. firmware management. Part Number: 679349-001 July 2012 Edition: 1The HP ProLiant ML310e Gen8 v2 Server is the newest addition to the ProLiant. Waiting for FreeNAS 11. BIOS Enhanced RAID The BIOS Enhanced RAID feature is a toggle setting that, when enabled, analyzes the Linux data on installed hard drives for failure information. We have a Proliant ml310e gen8 v2 that was perfect till yesterday it started shutting down for no apparent reason, there is nothing in the IML, and only the ILO event log showing these events: Server power removed. 000. Configuration Information - Factory Integrated Models. DL380e Gen8, 2x E5-2420, 32 GB, 6 fans, P420 controller, 2x750W PSU. Find the latest firmware and driver updates for your server, as well as manuals and guides, on this page. HPE ProLiant ML310e Gen8 v2 Server is a single-socket 4U tower server that offers essential availability and expansion for small businesses and remote offices. I have an old HP ProLiant ML301e Gen8 v2 Model 0 Server (P/N 717155-001) that was recently decommissioned. Install the access panel (on page 21). The HP ProLiant ML310e Gen8 Server has four memory slots. HP Smart Update Manager (SUM) locates the latest versions of Windows Server 2012 drivers. If the NSC has been updated with the NSC DVD, the firmware image files are located in the C: Non-SUT Firmware Lyy. 02-06-2015 02:52 AM. Price: $2,199. 20. I had similar performance issue on server HP ProLiant ML310e Generation 8 with HP Dynamic Smart Array B120i Controller. Manage privacy and data collection on HPE.